Baseline ESG Due Diligence Report

Case: Synthetic NYC Multifamily — 10001  |  Generated: July 16, 2026  |  Powered by Baseline Engine
SYNTHETIC VALIDATION CASE — NOT A CLIENT PROPERTY The property facts are scenario inputs. Annual utility consumption is generated directly from the matched DOE prototype-derived EUI, so the 1.0 calibration factors below test pipeline consistency rather than field accuracy. Every cost, savings, emissions, incentive, and compliance value is a modeled output that requires source verification before client or investment use. Inspect the methodology trace.
yr (IRR column updates on change)

Property

Asset type multifamily_midrise
Year built 2005
Location New York, NY, 10001
GFA 214,796 sqft
Units 220
Stories
PCA mode Enabled as a scenario flag; no source PCA is bundled with this report
HVAC system type Unknown — verify manually. ECM gating may be inaccurate.

PCA Capital Reserve Summary

No source PCA extraction data is bundled with this synthetic case; reserve values are intentionally blank.
System Condition Est. Useful Life Remaining Replacement Cost Est. Recommended Reserve ($/yr)
Roof N/a N/A N/A N/A
HVAC N/a N/A N/A N/A
Windows N/a N/A N/A N/A
DHW N/a N/A N/A N/A
Elevators N/a N/A N/A N/A
Plumbing N/a N/A N/A N/A

Total Recommended Annual Reserve: not modeled in this scenario

Baseline Energy & Emissions

Synthetic energy inputs: DOE prototype-derived 2004–2013 multifamily-midrise lookup for climate zone 4A (14.2 electric + 28.4 gas kBtu/sqft/yr). These are not utility-bill observations.

Synthetic electricity input 893,897 kWh/yr (14.2 kBtu/sqft)
Synthetic natural gas input 61,002.1 therms/yr (28.4 kBtu/sqft)
Archetype EUI input (total) 42.6 kBtu/sqft/yr
Electricity self-consistency ratio 1.0000
Gas self-consistency ratio 1.0000
Field calibration status Not field calibrated — synthetic inputs
Scope 1 (on-site combustion) 323.3 tCO2e/yr
Scope 2 (purchased electricity) 258.3 tCO2e/yr
Total GHG 581.6 tCO2e/yr
GHG intensity 0.002708 tCO2e/sqft/yr
eGRID subregion NYCW

Scenario BPS Routing

The engine routes ZIP 10001 to NYC Local Law 97, but this snapshot's numeric exposure path uses an older occupancy-group schedule. Current NYC reporting uses ENERGY STAR Portfolio Manager property-type limits. Numeric fines are therefore withheld from this public case until the lookup and property mapping are updated and revalidated.

Policy NYC Local Law 97
Jurisdiction routing Matched from ZIP 10001
Baseline GHG intensity 0.002708 tCO2e/sqft/yr
Numeric compliance result WITHHELD — current ESPM property-type mapping required
Current official reference NYC DOB LL97 Buildings Emissions Limits

Energy Conservation Measures (ECMs)

Savings, installed costs, incentives, and returns are lookup-driven screening estimates. Confidence refers to the source delta, not to realized savings at a field-verified property.

Applicable ECMs (with delta data) 6
Suppressed ECMs (pending delta data) 11
Total net savings yr1 (all ECMs) $88,413
Total GHG savings 251.6 tCO2e/yr
Total capex (gross) $1,525,192
Total capex (net) $952,452
Total ECM-level incentives $572,740
BPS fine avoidance PV Not published from this engine snapshot
Measure Life Gross Cost Incentives Net Cost Energy Savings
(kBtu/yr)
GHG Savings
(tCO2e/yr)
Payback ROI IRR Delta source confidence
Install No-Export Rooftop PV System 25 yr $676,274 $250,340 $425,934 890,630.1 kBtu 75.4 tCO2e 9.1 yr 11.0% 3.9% Medium
Install Domestic Hot Water Heat Pump Water Heater 15 yr $319,000 $319,000 $0 2,311,978.2 kBtu 116.5 tCO2e High
Install LED Lighting
Cost assumes full fixture replacement ($0.85/sqft). If relamping only, reduce estimate by ~65% ($0.30/sqft).
15 yr $2,200 $2,200 $0 167,755.7 kBtu 14.2 tCO2e High
Install Energy Recovery Ventilation (ERV) 20 yr $319,000 $0 $319,000 366,012.4 kBtu 21.3 tCO2e 46.4 yr 2.2% -19.7% Medium
Replace Boiler with High-Efficiency Condensing Unit 25 yr $112,060 $0 $112,060 335,511.4 kBtu 17.8 tCO2e 27.8 yr 3.6% -13.9% Medium
Air Sealing / Infiltration Reduction 20 yr $96,658 $1,200 $95,458 115,903.9 kBtu 6.3 tCO2e 58.2 yr 1.7% -22.2% Medium
11 suppressed ECMs (delta data pending)

Water & DHW Savings

Units analyzed 220
Occupants per unit 2.5
Water savings 6,484,225 gal/yr
Water cost savings $64,842
DHW energy savings 1,457,244 kBtu/yr
DHW cost savings $17,487
DHW GHG savings 77.23 tCO2e/yr
Total fixture savings $82,329
Fixture Water Savings (gal/yr) Water Cost Savings DHW Energy (kBtu) DHW Cost Savings Total Savings/yr
toilet 2,228,325 $22,283 0 $0 $22,283
showerhead 2,569,600 $25,696 1,097,219 $13,167 $38,863
lavatory_faucet 1,365,100 $13,651 291,449 $3,497 $17,148
kitchen_faucet 321,200 $3,212 68,576 $823 $4,035

DHW cost savings use gas rate $1.2000/therm. If building uses a blended heating rate, verify against pure gas rate for DHW-only ECMs.

Incentives Summary

State NY
PACE financing available Yes
ECM-level incentives total $1,251,406

Portfolio incentives total: $2,503,980 (if eligible; verify before use)

Portfolio-Level Incentives (not deducted from ECM CapEx)
Program Type Amount Basis Confidence Notes
IRA Section 179D Commercial Buildings Energy Efficiency Tax Deduction tax_deduction $1,073,980 $5.00/sqft × 214,796 sqft High Deduction (not credit) of up to $5/sqft for commercial buildings achieving 25%+ energy reduction vs ASHRAE 90.1-2007. Applies to multifamily 4+ stories. Full $5/sqft requires 50%+ reduction; partial deduction available at $2.50-$5/sqft for partial qualifying systems. Requires third-party certification.
IRA Section 45L Energy Efficient Home Credit — Multifamily New Construction & Retrofit tax_credit $550,000 $2,500/unit × 220 units High IRA expanded 45L for 2023+. $2,500/unit for ENERGY STAR certified multifamily; $5,000/unit for DOE Zero Energy Ready. Applies to new construction AND substantial reconstruction (gut rehab). Not available for incremental retrofit without full energy certification. Flag for ground-up or major rehab projects only.
IRA HOMES Rebate Program — Whole-Building Retrofit rebate $880,000 $4,000/unit × 220 units Medium IRA HOMES (Home Efficiency Rebates). State rollout varies — most states still developing programs as of early 2025. Flag applicable for affordable/LIHTC multifamily achieving 35%+ whole-building energy savings. Rebate is per dwelling unit; common-area-only retrofits do not qualify. Verify state rollout status before presenting to client.
DISCLAIMER: This report is generated from archetype-based engineering estimates and is intended for preliminary due diligence only. All incentive amounts and ECM screening outputs must be verified against current official sources before use in investment decisions, client reporting, or regulatory submissions. Incentive programs are subject to change and expiration. Numeric BPS exposure is intentionally withheld pending an update to current ESPM property-type limits.